Cooperation competitions "CO" and "PC" of DX500RALLY Support Site

Cooperation competitions "CO" and "PC"

It corresponds to the pattern of the following four types.

Doticon_wht_Right.png(1)Start of "PC" and start of "CO" are the same
copc_01.jpg

Doticon_wht_Right.png(2)Goal of "PC" and goal of "CO" are the same
copc_02.jpg

Doticon_wht_Right.png(3)The start of the "PC" goal of "CO"
copc_03.jpg

Doticon_wht_Right.png(4)The start of "CO" goal of "PC"
copc_04.jpg

Example

The start of "CO1" start of "PC1"
The goal of "CO1" goal of "PC6"

copc_01_01.jpgデータの入力イメージです。

Doticon_wht_Right.png coordinate the start of "CO1" and start of "PC1".
copc_01_02.jpg
The input area of "CO cooperation" under, enter the number of the "CO" want to work together to select the "Start" in the selector.

The operation screen, I will start to count down operation of the CO1 at the same time as the start of SPC1 (Start PC) ⇒ PC1.
Real_col_Attention.pngYou do not need to start the cooperation of "CO" and, "PC" if you do not need a clear start time of "CO1".

Doticon_wht_Right.png coordinate the goal of "CO1" the goal of "PC6".
copc_01_03.jpg
The input area of "CO cooperation" under, enter the number of the "CO" want to work together to select the "goal" in the selector.

In the operation screen, I will make the countdown of up to "CO1" goal.
Real_col_Attention.pngIn the example, the total time of up to PC4 ~ PC6 is because it is 27 seconds, start time of PC4 is the fact that 27 seconds before the arrival time minus the CO1.

ページトップへ

Operation screen

Doticon_wht_Right.pngThe operation on the operation screen, the data input.

copc_02_01.jpg
That PC1 and CO1 is start cooperation, but it is free start for CO1 so many, it is also possible that would be operated by selecting CO1 ahead.
In this case, is calculated from the time and mileage from the time that has passed the start time, and then calculates and displays the speed always necessary to reach to the goal Ave..

copc_02_02.jpg
If you by linking the start of PC1 and CO1, you want to run at the same time, by selecting the SPC1, and the competition waiting state.
Press the check button, CO1 PC1 and will start at the same time.
Real_col_Attention.pngAfter the start, When you digestion the PC3, control is transferred to SPC2, you becomes the start wait of PC4, but if you want to traveling the liaison interval, When you to liaison mode by Double-tap the hold button, to see control of pieces illustration Feed, you can that you want to assign to the hand switch.

copc_02_03.jpg
Goal of CO1 goals and PC6 Because of the cooperation, countdown until the start time of PC4 is displayed.
At the same time as the goal of PC6, CO1 will end.

ページトップへ